VKC ScienceChemistry for written exams Telegram

VKC Blog

PYQs explained, strategy, answer writing and video notes for UPSC Chemistry

All posts

Clausius–Clapeyron equation: derivation, and why water boils at 81 °C at half an atmosphere

By Vimal Swarnkar (VKC) · UPSC Chemistry · Civil Services, Combined Geo-Scientist and IFoS

Halve the pressure over water and it boils almost 19 degrees lower. One equation explains it, and UPSC asks that equation, or a numerical built on it, almost every year. In this post I will show you how often it comes, which book to use, how I plan the answer, and how the answer should look in your booklet.

Daily answer writing, Day 07, 10 marks (5 + 5) · built on IFoS 2025 Paper I Q4(a)(i) and IFoS 2021 Paper I Q4(c)

(a) Starting from the Clapeyron equation, derive the Clausius–Clapeyron equation for liquid ⇌ vapour equilibrium. State the assumptions you make. (b) Estimate the boiling point of water at 0.5 atm. (ΔvapH = 40.7 kJ mol−1, normal boiling point = 373.15 K)

Short answer

On the liquid–vapour line μl = μg, which gives the Clapeyron equation dp/dT = ΔvapH / TΔV. Take Vl ≪ Vg, the vapour as ideal (Vg = RT/p) and ΔvapH constant: d ln p/dT = ΔvapH/RT2, and on integrating ln(p2/p1) = −(ΔvapH/R)(1/T2 − 1/T1). With p1 = 1 atm at 373.15 K and p2 = 0.5 atm, 1/T2 = 2.8215 × 10−3 K−1, so water boils at 354.4 K = 81.3 °C.

Watch the video

Day 07 of my Daily Answer Writing series on YouTube: I derive the equation from the Clapeyron equation and work the 0.5 atm numerical the way it should go into your booklet.

Open on YouTube

A word from me

Most students know the final formula by heart. Where they lose marks is everything around it: they start from the integrated form without deriving it, they forget to state the assumptions, or they get the sign wrong and find that water boils at a higher temperature on a mountain. The examiner gives the marks for the steps, not for the last line.

So learn it as one chain: μl = μg, then the Clapeyron equation, then the three assumptions as a set (Vl ≪ Vg, ideal vapour, ΔvapH constant), then the integration. Write it once by hand from one book, and then do every numerical with the same line, putting T in kelvin and ΔvapH in joules. If you get stuck, ask me on Telegram at t.me/upsc_chemistry_vkc.

55 marks in five years

From 2021 to 2025, the Clausius–Clapeyron equation was asked directly 5 times, for 55 marks: Civil Services 2021 Q1(d) (vapour pressure of water at 100 °C from its value at 95 °C, 10 marks), Civil Services 2022 Q4(b) (ΔvapH of water from two vapour pressures, 10 marks), Civil Services 2024 Q4(a) (triple point and enthalpy of sublimation from two ln p equations, 15 marks), IFoS 2021 Q4(c) (the derivation, 15 marks) and IFoS 2025 Q4(a)(i) (boiling point of water at 380 torr, 5 marks). Phase diagrams of one-component systems came in 6 more questions in the same years. Today’s question is the IFoS 2025 numerical with the IFoS 2021 derivation in front of it.

Syllabus and books

In Civil Services it is Paper I, Unit 7, Phase equilibria and solutions. IFoS asks it in Paper I and the Geo-Scientist exam in Mains Chemistry Paper II. The Civil Services syllabus reads:

“Phase equilibria and solutions: Clausius–Clapeyron equation; phase diagram for a pure substance; phase equilibria in binary systems …”

The equation is named in the syllabus itself, so it is fair game every year, both as a derivation and as a numerical.

You do not need all of these books. Any one of them is enough for this question.

  • Book 1: Atkins’ Physical Chemistry (9th edition), Chapter 4, Section 4.3 “The location of phase boundaries”: the Clapeyron equation and the liquid–vapour boundary.
  • Book 2: Puri, Sharma and Pathania, Principles of Physical Chemistry, the Clapeyron–Clausius equation and its applications, with solved numericals.
  • Book 3: Silbey, Alberty and Bawendi, Physical Chemistry, one-component systems: the Clapeyron and Clausius–Clapeyron equations.

How to build the answer

Read the tree from left to right. Every leaf is a point to write, in that order. The highlighted words are the ones the examiner looks for.

Clapeyron → Clausius–Clapeyron with assumptions; then the boiling point of water at 0.5 atm
Introduction

Given information

  • H2O(l) ⇌ H2O(g), one component, two phases
  • (b) ΔvapH = 40.7 kJ mol−1, Tb = 373.15 K

Starting point

  • On the curve μl = μg
  • dμ = −SmdT + Vmdp

Key law

  • Clapeyron: dp/dT = ΔvapH / TΔV
Body

Assumptions

  • Vl ≪ Vg
  • vapour ideal: Vg = RT/p
  • ΔvapH constant

Derivation

  • d ln p/dT = ΔvapH/RT2, boxed
  • ln(p2/p1) = −(ΔvapH/R)(1/T2 − 1/T1), boxed

Values

  • 1/T2 = 2.8215 × 10−3 K−1
  • T2 = 354.4 K = 81.3 °C

Check and sketch

  • p falls, so Tb falls ✓; J and K
  • p–T curve with 1 and 0.5 atm marked
Conclusion

Reading the result

  • ln p vs 1/T a straight line, slope −ΔvapH/R

Principle

  • fails near the critical point

Application

  • high mountains (81 °C); pressure cooker (121 °C at 2 atm)

Final answer

  • the integrated form and Tb = 354.4 K, double underlined

Two pictures that earn marks

0.511.522.5330340350360370380390400temperature, T / Kvapour pressure, p / atm1 atm · 373 K (100 °C)0.5 atm · 354 K (81 °C)2 atm · 394 K (121 °C)LIQUIDVAPOURslope dp/dT = ΔH / TΔV
Figure 1. The liquid–vapour line of water. Its slope at every point is the Clapeyron slope ΔvapH/TΔV. Water boils where its vapour pressure equals the outside pressure: 373 K at 1 atm, 354 K at 0.5 atm and 394 K at 2 atm.
−1.0−0.50+0.5+1.02.502.552.602.652.702.752.802.852 atm · 394 K1 atm · 373 K0.5 atm · 354 Kdown by ln 2 = 0.693slope = −ΔvapH / R ≈ −4900 K1000 K / Tln (p / atm)
Figure 2. The same data as ln p against 1/T: a straight line of slope −ΔvapH/R ≈ −4900 K. Halving p moves down by ln 2 = 0.693, which moves 1/T to the right by 0.693 × R/ΔvapH, and the boiling point falls to 354 K.

What gains marks

  • The start: μl = μg on the curve, so dμl = dμg, with dμ = −SmdT + Vmdp.
  • The exact Clapeyron equation, dp/dT = ΔvapH / T(Vg − Vl), boxed and named.
  • All three assumptions, numbered: Vl ≪ Vg; ideal vapour; ΔvapH constant over the range.
  • d ln p/dT = ΔvapH/RT2, boxed, and the integrated form with the right sign.
  • In the numerical: boiling means vapour pressure = outside pressure; T in kelvin and ΔvapH in J mol−1; the answer in K and °C.
  • A p–T sketch with 1 atm and 0.5 atm marked, a check line, and one application: mountains or the pressure cooker.

Match the length to the marks

I always tell my students to let the marks decide the length. For 5 marks, as in IFoS 2025 Q4(a)(i), I would write the integrated equation with one line on the assumptions and then the numerical: half a page. For 10 marks, as here, write the full chain from μl = μg and add the sketch: about two pages. For 15 marks, as in IFoS 2021 Q4(c) or Civil Services 2024 Q4(a), add the ln p vs 1/T graph, where the equation fails, and a second numerical such as the triple point from two ln p equations.

How it looks in the booklet

This is the full 10-mark answer, in the order of the tree above. Page 1 derives the equation, and page 2 does the numerical and the conclusion.

Page 1 of 2 · Introduction and part (a)System, Clapeyron, assumptions, derivation

Q.)(a) Derive the Clausius–Clapeyron equation from the Clapeyron equation, stating the assumptions. (b) Boiling point of water at 0.5 atm (ΔvapH = 40.7 kJ mol−1, Tb = 373.15 K). [IFoS 2025, 5 marks; IFoS 2021, 15 marks]

Ans.Given: H2O(l) ⇌ H2O(g), one component, two phases in equilibrium.

On the coexistence curve μl = μg, so along the curve dμl = dμg. With dμ = −SmdT + Vmdp,

−SldT + Vldp = −SgdT + Vgdp, i.e. dp/dT = ΔS/ΔV, and at the transition ΔS = ΔvapH/T. So

35437310.5p/atmT/Kliquidvapour
dpdT=ΔvapHT(Vg−Vl)— — (i)

This is the exact Clapeyron equation.

(a) Assume that

  1. i) Vl ≪ Vg (18 cm3 against about 30 600 cm3 per mole at 373 K), so ΔV ≈ Vg;
  2. ii) the vapour is ideal: Vg = RT/p;
  3. iii) ΔvapH is constant over the small range of T.

So, putting i) and ii) in (i), we get

dlnpdT=ΔvapHRT2— — (ii)

Integrating (ii) from (p1, T1) to (p2, T2) with iii),

lnp2p1=−ΔvapHR(1T2−1T1)— — (iii)

This is the Clausius–Clapeyron equation; ln p against 1/T is a straight line.

All other symbols have their usual meaning.

Page 2 of 2 · Part (b) and conclusionNumerical, check, reading, application

(b) A liquid boils when its vapour pressure equals the outside pressure. So p1 = 1 atm at T1 = 373.15 K and p2 = 0.5 atm. From (iii),

1T2=1T1−RΔvapHlnp2p1=1373.15+8.314×0.69340700— — (iv)

1/T2 = 2.6799 × 10−3 + 0.1416 × 10−3 = 2.8215 × 10−3 K−1

T2 = 354.4 K = 81.3 °C— — (v)

Check: p falls, so Tb falls ✓; ΔvapH in J (40 700), not kJ; T in kelvin ✓. The IFoS 2025 data (40.65 kJ mol−1, 380 torr) give the same 354.4 K.

Outside pressure / atm0.512
Boiling point of water354.4 K (81.3 °C)373.15 K (100 °C)394.0 K (120.8 °C)

Conclusion:

  1. i) ln p against 1/T is a straight line; its slope gives ΔvapH from two vapour pressures.
  2. ii) Halving p lowers Tb by about 19 K: water on high mountains boils near 81 °C, so food cooks slowly.
  3. iii) The same equation at 2 atm gives 394 K ≈ 121 °C: the pressure cooker.
  4. iv) It fails near the critical point, where Vl is not ≪ Vg and ΔvapH → 0.

So, ln(p2/p1) = −(ΔvapH/R)(1/T2 − 1/T1); Tb(0.5 atm) = 354.4 K = 81.3 °C

The same question in other exams

IFoS 2025, Paper I, Q4(a)(i), 5 marks: ΔvapH = 40.65 kJ mol−1, Tb = 373.15 K; boiling point on a 5500 m mountain where p = 380 torr. 380 torr is exactly half of 760 torr, so this is part (b) above: 354.4 K (81.3 °C).

IFoS 2021, Paper I, Q4(c), 15 marks: derive the Clausius–Clapeyron equation for water (l) ⇌ water (g). This is part (a) above; for 15 marks add the ln p vs 1/T graph and where the equation fails.

Civil Services 2021, Paper I, Q1(d), 10 marks: p = 634 mm at 95 °C, ΔvapH = 40 593 J mol−1; find p at 100 °C. ln(p2/634) = (40 593/8.314)(1/368.15 − 1/373.15) = 0.1777, so p ≈ 757 mm, just short of 760 mm, as it should be.

Civil Services 2022, Paper I, Q4(b), 10 marks: p = 529 torr at 363.2 K; find the average ΔvapH up to 373.2 K. Take p = 760 torr at the normal boiling point: ΔvapH = R ln(760/529)/(1/363.2 − 1/373.2) = 40.8 kJ mol−1.

Civil Services 2024, Paper I, Q4(a), 15 marks: ln pl = −3010/T + 13.2 and ln ps = −3820/T + 16.1. Each line is equation (iii) with slope −ΔH/R. Setting them equal gives the triple point, 279.3 K and 11.3 bar, and ΔsubH = 3820R = 31.8 kJ mol−1.

Every version is the same line, ln(p2/p1) = −(ΔvapH/R)(1/T2 − 1/T1): you are given three of the four quantities and asked for the fourth, or given the slope of ln p against 1/T and asked for ΔH. Learn the derivation once and every numerical is one substitution.

Questions students ask

How do you derive the Clausius–Clapeyron equation from the Clapeyron equation?

Start from the Clapeyron equation dp/dT = ΔvapH / T(Vg − Vl). Assume Vl is negligible beside Vg, the vapour is ideal (Vg = RT/p) and ΔvapH is constant. Then d ln p/dT = ΔvapH/RT², and integrating between (p1, T1) and (p2, T2) gives ln(p2/p1) = −(ΔvapH/R)(1/T2 − 1/T1). This derivation was asked in UPSC IFoS 2021, Chemistry Paper I, Q4(c), for 15 marks.

What is the boiling point of water at 0.5 atm?

About 354.4 K, or 81.3 °C. With ΔvapH = 40.7 kJ/mol and the normal boiling point 373.15 K at 1 atm, 1/T2 = 1/373.15 + (8.314 × ln 2)/40700 = 2.8215 × 10⁻³ K⁻¹. UPSC IFoS 2025, Paper I, Q4(a)(i) asked the same with 380 torr, which is half of 760 torr.

What are the assumptions of the Clausius–Clapeyron equation?

Three: the molar volume of the liquid is negligible compared with that of the vapour; the vapour behaves as an ideal gas, so Vg = RT/p; and the enthalpy of vaporisation is constant over the temperature range used. The exact Clapeyron equation needs none of them.

Why does water boil at a lower temperature on high mountains?

A liquid boils when its vapour pressure equals the outside pressure. Higher up the air pressure is lower, so water reaches that pressure at a lower temperature. At half an atmosphere water boils at about 81 °C, so food cooks slowly. A pressure cooker does the opposite: at 2 atm water boils at about 121 °C.

Why is a plot of ln p against 1/T a straight line?

The integrated Clausius–Clapeyron equation can be written ln p = −ΔvapH/(RT) + constant. If ΔvapH is constant, ln p is linear in 1/T with slope −ΔvapH/R. For water the slope is about −4900 K, and ΔvapH can be found from the slope or from two vapour pressures.

How often does UPSC ask the Clausius–Clapeyron equation?

From 2021 to 2025 it was asked directly 5 times for 55 marks: Civil Services 2021 Q1(d), 2022 Q4(b) and 2024 Q4(a), and IFoS 2021 Q4(c) and 2025 Q4(a)(i). Phase diagrams of one-component systems came in 6 more questions in the same years.

Read the complete answers

By VKC, your mentor. Integrated M.Sc. Chemistry, IIT Roorkee. CSIR NET Chemical Sciences, All India Rank 4. New posts are announced first on Telegram.